S6600 Anesthesia Machine

Application
The anesthesia machine performs well in Intensive Care Units (ICU), Operation rooms, Anesthesiology departments, and other departments.

Function
With advanced ventilation modes, and professional design for adults, children, and neonatal inhalation anesthesia and respiratory management.

  • 15″ TFT LCD touch screen displays the Ventilation parameters, Alarm information and Oscillographs.
  • Electronic flow meter, instantly know the fresh gas flow to your patient. Integration breathing circuit design, ensures easy
    operation and keeps it tidy.
  • Multiple working modes such as volume control and pressure limit, adapt to wide range patient.
  • Vaporizer with temperature, flow compensation and self-lock function, keep safety anytime.
  • Multiple parameters monitoring interface, make every parameter clear, let users know the patient conditions in all aspects.
  • Pressure-time, flow-time, pressure-volume , volume-time, Pressure-Volume,Flow-volume and ETCO2-time.P-F Volume
  • Patient Monitor and AG monitoring are optional.

Shipping nationwide

  • Check Mark Satisfaction Guaranteed
  • Check Mark No Hassle Refunds
  • Check Mark Secure Payments
SECURE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
Category:

Description

Application
The anesthesia machine performs well in Intensive Care Units (ICU), Operation rooms, Anesthesiology departments, and other departments.

Function
With advanced ventilation modes, and professional design for adults, children, and neonatal inhalation anesthesia and respiratory management.

  • 15″ TFT LCD touch screen displays the Ventilation parameters, Alarm information and Oscillographs.
  • Electronic flow meter, instantly know the fresh gas flow to your patient. Integration breathing circuit design, ensures easy
    operation and keeps it tidy.
  • Multiple working modes such as volume control and pressure limit, adapt to wide range patient.
  • Vaporizer with temperature, flow compensation and self-lock function, keep safety anytime.
  • Multiple parameters monitoring interface, make every parameter clear, let users know the patient conditions in all aspects.
  • Pressure-time, flow-time, pressure-volume , volume-time, Pressure-Volume,Flow-volume and ETCO2-time.P-F Volume
  • Patient Monitor and AG monitoring are optional.

Specifications
Ventilation Modes
Manual, (V-CMV)IPPV, (P-CMV)PCV, (P-S1MV), (V-S1MV), PSV, PRVC

Main Ventilator Parameter
Tidal Volume (VT): 0, 10 mL ~ 1500 mL
Frequency (Freq): 4bpm ~ 100 bpm
I/E: 4:1~1:10

Ventilator Parameter
PEEP: 0cmH2O ~ 30 cmH2O

Monitored Parameters
Rapid Oxygen: 35L/min-75L/min
Pressure Trigger: 0.3 L/min, 1L/min~15L/min
Pressure Support: 3cmH2O~50cmH2O
Inspiration Apnea: OFF, 5%~60%
Pressure Limit: 10cmH2O~100cmH2O
Inspiration Time: 0.2s~5s
Trigger: 5%~95%
SIMV Frequency: 4bpm~60bpm
Frequency (Freq): 0bpm~120bpm
Tidal Volume (Vt): 0mL~1500mL
Minute Volume: 0L/min~100L/min
Oxygen Concentration: 15 % ~ 100 %
Airway Pressure
PEEP

Oscillographs display
P-T, V-T, F-T, P-V, F-V, F-P, ETCO2

Alarm and protection
14 kinds of alarm information